Incinerator Rated Capacity: 100/KG/Hr Type of Design: Double Chambered Mode of Heating: Heating Elements  Primary Combustion Chamber  Waste Charging Door: Provided with refractory lining with sealing gaskets  Ash Removed Door: Provided with refractory lining with sealing gaskets  Outer Body MOC: Mild Steel, 5mm  Primary Chamber: Stainless Steel  Operating Temperature :800. ± 50◦C  Insulation: Insulation Brick  Heating Elements Type: Kanthal Al Grade Power Consumption: 75 KW ( Initial Load )  Electrical Supply :3 Phase 440 Volt  Control Panel  MOC: Mild Steel Power Coated No. of Temp: Controllers : 2 Nos  Details: The Control Panel will be provided with contract as relays , switches , indicators etc . Operative on 3 phase. […]
Incinerator Rated Capacity: 100/KG/Hr Type of Design: Double Chambered Mode of Heating: Heating Elements  Primary Combustion Chamber  Waste Charging Door: Provided with refractory lining with sealing gaskets  Ash Removed Door: Provided with refractory lining with sealing gaskets  Outer Body MOC: Mild Steel, 5mm  Primary Chamber: Stainless Steel  Operating Temperature :800. ± 50◦C  Insulation: Insulation Brick  Heating Elements Type: Kanthal Al Grade Power Consumption: 75 KW ( Initial Load )  Electrical Supply :3 Phase 440 Volt  Control Panel  MOC: Mild Steel Power Coated No. of Temp: Controllers : 2 Nos  Details: The Control Panel will be provided with contract as relays , switches , indicators etc . Operative on 3 phase. […]
Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS Medical Waste Incinerator, 100 to 120 Kg/hr Application   For incineration, general and pathological Capacity    100 C 120 kg/h burn rate Type Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time                Minimum 8 hours daily Operating temperature     From 850 0C to 1200 0C, Automatic controlled Residual Ash                    5 to 10% Construction Constructed from heavy duty mild or aluminized  steel Or equal and approved equivalent […]
Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS Medical Waste Incinerator, 100 to 120 Kg/hr Application   For incineration, general and pathological Capacity    100 C 120 kg/h burn rate Type Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time                Minimum 8 hours daily Operating temperature     From 850 0C to 1200 0C, Automatic controlled Residual Ash                    5 to 10% Construction Constructed from heavy duty mild or aluminized  steel Or equal and approved equivalent […]
Medical Waste Incinerator, 50 to 60 Kg/hr Support Health Sector Support Project Point of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals 1.    General Description Supply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment.  The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006).  The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual.  The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour.  It shall be constructed from mild or aluminized steel lined with refractory material. Main unit Application For incineration, general and pathological Capacity   50 C 60 kg/h burn rate Type Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time                Minimum 8 hours daily Operating temperature     […]
Medical Waste Incinerator, 50 to 60 Kg/hr Support Health Sector Support Project Point of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals 1.    General Description Supply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment.  The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006).  The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual.  The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour.  It shall be constructed from mild or aluminized steel lined with refractory material. Main unit Application For incineration, general and pathological Capacity   50 C 60 kg/h burn rate Type Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time                Minimum 8 hours daily Operating temperature     […]